Fire door inspection reports, drafted from field notes for your inspector to sign.
Your inspector walks a building door by door and comes back with notes and photos, and then someone has to turn those into a report for the owner and a repair quote. In a free AI proof of concept, AI drafts both from copies of 20 to 30 inspections your team already closed. Your reviewer, the person on your staff who knows this work best, compares each draft with what you actually delivered.
- Past inspections
- 20 to 30
- Doors certified
- None
- Reports signed
- None
// The one job
From a walk-through to a report and a quote someone can sign
An inspector walks the building with a door list, a gauge and a camera, works each fire door through its full close and latch, and writes down what passed and what didn't. Back at the office, someone types that into a report for the building's owner, line by line and door by door, then builds the repair quote from the same notes.
In the test, AI reads copies of those notes and photos and drafts the report and the quote behind it: each opening and its location, each listed item as your inspector marked it, each deficiency with its photo, and one quote line per deficiency at your own rates. Nothing is certified, signed or sent, and your reviewer sets every draft beside the report and quote you issued.
door by door
// What makes it hard
Where an inspection report goes wrong
One door, one form, and the lines move with the edition. The Kansas State Fire Marshal's Form 817, revised March 31, 2026, wants a separate form for each fire door and runs eleven pass or fail lines under the 2010 edition of NFPA 80, from open holes through gasketing. A July 2026 article in Buildings magazine lists thirteen criteria, with a legible label and door signage among them. Which version applies turns on what the jurisdiction has adopted, so your reviewer sets the edition and the form before the first draft, and every draft keeps your inspector's answer on each line.
A gap is a number on a named edge. The same Kansas form allows at most 3/4 inch under the bottom of a door, or 3/8 inch where that bottom sits more than 38 inches above the finished floor. At the top and vertical edges and between a pair, it calls for 1/8 inch, give or take 1/16, on steel and no more than 1/8 on wood, measured from the pull face. A note that says "big gap at head" can't fill that line. Pairs with a coordinator have their own line too, because the inactive leaf has to close first. The draft carries the reading your inspector wrote and leaves a line open when the notes give no number.
Hospitals split the door list. CMS memo S&C 17-38-LSC, dated July 28, 2017, requires annual inspection and testing under the 2010 edition of NFPA 80 for all fire door assemblies in health care occupancies. Non-rated doors, including corridor doors to patient care rooms and smoke barrier doors, fall outside that rule and belong in routine maintenance, and fire door deficiencies get cited under K211. So a hospital report keeps rated and non-rated openings apart, using your inspector's own call. Life Safety Code chapters for assembly, education and day care occupancies carry a separate door inspection reference, which your reviewer can add to the form.
A missing label is not a parts line. The Steel Door Institute says a removed label can't be put back, and that holes other than fastener holes count as field modifications. Intertek's field labeling page gives the usual reasons for field work: modifications, doors that left the factory without labels, incorrect labeling, labels painted over or removed. It says a certified or listed party has to do the labeling. Each quote therefore separates what your crew can repair, what gets replaced, and what needs a labeling service, and the draft sends that last kind to a person with no price on it.
The record outlives the walk-through. The Institute notes inspection records are kept three years unless otherwise specified and acceptance test records for the life of the assembly, that deficiencies get fixed without delay, and that some authorities want them addressed within 60 days. NFPA 80 doesn't name a required certificate, though DHI runs a Certified Fire and Egress Door Assembly Inspector credential. Your reviewer will watch for a line marked without a note behind it, a deficiency with no quote line, photos filed under the wrong door, and anything that sounds like a compliance ruling. These rules are summarized for context, not as code advice.
// What you send
Inspections your team already closed
20 to 30 finished inspections
Signed reports across several buildings and occupancies. Include a hospital or clinic if you inspect them, a building with many deficiencies, and one report your team had to correct.
The field notes and photos
Handwritten sheets, tablet exports or checklists, along with the photos your inspector took, so the draft reads what the office read.
The repair quotes that followed
Each quote built from those reports, plus the labor and parts rates your office used at the time, written as they appear in your own files.
Copies, once the NDA is signed
Remove any photo showing a patient, a student or a security detail before it moves. Nobody from Massmarket opens your inspection app or ERP. Files that can't leave the office get look-alikes, built with your reviewer.
// Before it starts
Agreed before any report is copied
Your owner confirms each of these before a single inspection leaves the office.
- Your reviewer
- The owner's pick: often your lead inspector or program manager
- Success criteria
- In writing: which lines must match, and how open lines count
- Edition and form
- Named by your reviewer, for each jurisdiction in the sample
- Who decides
- Your qualified person, on every result and every signature
- Price
- A range for running it live, given up front
- NDA
- Signed ahead of any copying
// How the test is judged
The report you delivered beside each draft
| Across the same 20 to 30 inspections | Report and quote you issued | Draft from the test |
|---|---|---|
| Openings listed, identified as on your report | Completed on your inspections | Completed on your inspections |
| Each inspection line, as your inspector marked it | Completed on your inspections | Completed on your inspections |
| Clearance readings carried from the notes | Completed on your inspections | Completed on your inspections |
| Deficiencies with their location and photo | Completed on your inspections | Completed on your inspections |
| Repair quote lines, one for each deficiency | Completed on your inspections | Completed on your inspections |
| Lines left open for a person, with the reason | Completed on your inspections | Completed on your inspections |
| Time from field notes to a draft ready to sign | Completed on your inspections | Completed on your inspections |
// After a yes
About a month of live inspections
With your reviewer's yes, new walk-throughs get the same drafting for roughly 30 days.
Every report waits for your qualified person to review and sign it, and every quote waits for someone on your team before it reaches a building's owner.
Your reviewer keeps comparing drafts with what goes out. Any further job is a separate decision with its own price.
// Possible next jobs
After inspection reports, if you want more
- 01Next
Repair work orders
Approved quote lines grouped by building and crew, with the parts each opening needs called out for your service manager.
- 02Then
Next year's door lists
Last year's openings and open deficiencies carried into a list for the next walk-through at each building.
- 03After that
Door hardware schedules
Draft schedules from the Division 08 section and hardware sets, if your detailers want the same kind of test.
// One hard limit
A qualified person signs every inspection.
The proof of concept never touches a live report or your detailing, estimating or ERP system. It never certifies a fire door, never decides whether an opening complies, never signs a report and never contacts a building's owner or an authority having jurisdiction. It organizes what your inspector recorded, and a qualified person on your team reviews and signs. Rules named on this page are general information, not legal or code advice.
Priced per job. You get a range before the proof of concept and a fixed price before you sign.
Rob sets the range on the call, once he knows how many buildings you inspect in a year and how many fire doors a typical one has.
// Questions
Fire door inspection questions
Does the AI inspect or certify fire doors?
Our inspectors use an app and some still use paper. Does that matter?
Which edition of NFPA 80 does the draft follow?
Can it handle hospitals, where surveyors look at doors differently?
Does it price the repair quote?

Rob Eason, founder
// Book a proof of concept call
Start from last season's closed inspections.
A half-hour call with Rob covers your inspectors, the kinds of buildings you walk and about how many inspections you close each year. Reports, notes and photos stay in your office until the NDA is signed.
- Co-owned a 60-employee financial services firm and sold his share to his partner.
- Ran GOSO Technologies, a Boston solar company rated 5/5 across 24 Google reviews.
- 5/5 across 83 reviews in HighLevel's Certified Admin Directory.
- 4.3/5 from 6 Google reviews of Massmarket AI.
- Every directory and Google review, critical ones included, is shown word for word at massmarket.ai/reviews.
- Takes every proof-of-concept call himself.