Medical gas testing records drafted from your crew's logs, before the verifier is booked.
Installer testing records for medical gas and vacuum piping in hospitals, surgery centers and clinics, tested as a free AI proof of concept on 20 to 30 records your crews already signed. AI reads the daily logs, pressure readings and gauge photos behind each area, drafts the record test by test and gas by gas, and lists every blank the logs leave. Your foreman compares each draft with the record the crew signed.
- Past records
- 20 to 30
- Tests passed or signed by AI
- None
- Contact with verifiers
- None
// The one job
The crew runs the tests. Somebody still has to write them up.
Take a surgical suite renovation in a hospital wing: new outlets for oxygen, medical air and vacuum, nitrous oxide in two rooms, a WAGD line, zone valve boxes and an area alarm. Before a verifier is booked, your crew runs the installer tests one system at a time and logs them: pressures with start and stop times, a photo of each gauge, the outlets flowed for the cross-connection test, a leak found at a joint and rebrazed. Someone then writes up the area's testing record, pulls the brazing papers into the job file, and the ASSE 6010 foreman signs.
In the proof of concept, AI builds the draft testing record for each area from the same logs and photos, and lists every missing date, reading, hold time, witness and brazer record. It never marks a test passed, signs the record or speaks to a verifier. Your foreman sets each draft beside the record the crew actually signed.
test by test
// Where it gets hard
Seven tests, eight systems, and a witness who isn't on your payroll
The record lists seven tests, with a row for each system. The installer performance testing record Hamilton County Public Health in Ohio posts, revised in September 2014, says testing follows ASSE 6010 and NFPA 99, is done only by credentialed medical gas installers, and uses nitrogen NF; Kentucky's Department of Housing, Buildings and Construction posts a record of the same title. The tests run in order: initial blowdown, initial pressure test, initial pressure test for vacuum piping, initial cross-connection test one system at a time, piping purge, then 24-hour standing tests for positive pressure piping and for vacuum. Rows run from oxygen, medical air, nitrous oxide, carbon dioxide and nitrogen to instrument air, medical-surgical vacuum and WAGD, under the columns date, tested by, pass or fail, and test accepted by. The initial pressure test is at one and a half times working pressure with a 150 psig floor, and the standing vacuum test holds 12 inches of mercury.
Brazing papers come before the first joint. The 2025 California Plumbing Code wants installers certified to ASSE/IAPMO/ANSI 6010, and before any installation work it has the installer keep the brazing procedure and brazer qualification records on the job site. Those records state the filler metal, base metals, cleaning and joint clearance. A brazer qualifies on a test coupon examined visually and then sectioned, and stays qualified indefinitely unless more than six months pass without brazing under that procedure or there is a specific reason to doubt the brazer's ability. An employer relying on an outside group's procedure, or on a brazer's records from an earlier employer, signs and dates copies of them. The draft lists each brazer named in the logs and whether a record for that brazer is in the job file, and leaves whether it still holds to your foreman.
One test needs a witness, and the verifier wants proof of it. Under the same code, the 24-hour standing pressure test on positive pressure piping is witnessed by an ASSE 6020 inspector, an ASSE 6030 verifier, or the authority having jurisdiction or its designee, and a form showing it was performed and witnessed goes to the verifier when the verifier's tests begin. The standing vacuum test is witnessed by the authority having jurisdiction or its designee. Leaks found along the way are located, repaired or replaced, and retested. The draft lists a standing test with no witness named, and a repaired joint with no retest logged after it, as gaps for your foreman before anyone else asks.
The verifier is somebody else. New Mexico's medical gas rule, in force since November 15, 2019, has systems verified by third parties meeting ASSE 6030, who may not be, or work for, the installing contractor, the design professional or the manufacturer, or represent an equipment distributor, and no state or local inspector there issues a final inspection without complete documentation from the verifier. Installers there are certified journeymen meeting ASSE 6010, endorsed after a 32-hour course, recertified every three years and allowed up to two apprentices each on commercial work. The installer's record is the contractor's own, and this test stays on that side of the line.
What your foreman will check first: every system piped in the area listed under every test that applies to it, pressures and hold times carried from the logs into the right test, retests after a repair kept as their own entries, tested-by names that match certified installers on the job, and the accepted-by and witness lines left blank for the people who sign them.
// What you send
What the test needs from your medical gas jobs
20 to 30 signed testing records
Installer records as signed, one per area or phase, from several health care jobs, including some where a leak was found, repaired and retested.
The logs behind them
Daily reports, pressure logs, gauge photos, outlet lists and the zone drawings the crew worked from, in whatever form they were kept.
Brazing and installer papers
The brazing procedure and brazer qualification records and the ASSE 6010 cards from each job file, plus any witness forms that went to a verifier.
NDA first, look-alikes if needed
Hospital drawings and facility details are covered by the NDA, signed before anything moves. Where an owner won't release them, we build look-alike records with your foreman.
// Before it starts
Settled before the first log is copied
The owner names the judge and the pass mark before any record leaves the office.
- Reviewer
- Named by the owner. Often the ASSE 6010 foreman or the medical gas project manager.
- Success criteria
- In writing first, including how a wrong reading and a missed blank each count
- Records
- Drafted only. Never signed, witnessed or passed by AI
- Price
- A live-job range agreed before any copying starts
- NDA
- Signed before any log, drawing or record moves
// How it's judged
Each draft beside the record your crew signed
| Same 20 to 30 records | The signed record | The proof of concept |
|---|---|---|
| Every system in the area listed for each test | Filled in from your records | Filled in from your records |
| Dates, pressures and hold times carried from the logs | Filled in from your records | Filled in from your records |
| Leak repairs and retests kept as separate entries | Filled in from your records | Filled in from your records |
| Tested-by names matched to certified installers | Filled in from your records | Filled in from your records |
| A brazer record found for each brazer named | Filled in from your records | Filled in from your records |
| Witness and acceptance lines left for the right person | Filled in from your records | Filled in from your records |
// After a yes
About 30 days on the jobs you have open
After your foreman's yes, records for new areas are drafted for about 30 days as crews hand in their logs.
Every draft goes to the installer who ran the tests. They correct it, make every pass or fail call, sign it and hand it on to the verifier as they do today. No draft goes to a facility, an inspector or a verifier on its own.
The live job is priced at a fixed figure agreed after the test. Backflow reports, or another job, are priced on their own, and monthly support starts once a job is live.
// After medical gas records
What could come next
- 01Next
Backflow test reports
Each annual assembly test drafted from the tester's notes onto the water purveyor's form, for the certified tester to sign and file.
- 02Then
Installer and brazer register
Every installer's ASSE card number and renewal date, and each brazer's qualification records, kept in one list across all your jobs.
- 03After that
Zone valve and alarm lists
Zone valve boxes and area alarms listed from the drawings with the rooms and outlets each one serves, for your foreman to check against the labels.
// One hard limit
It drafts the record. It never signs, witnesses or passes a test.
The proof of concept never signs or certifies an installer testing record, never decides that a test passed, never witnesses or verifies a system, and never prices or sends a quote. It contacts no facility, verifier, inspector or authority having jurisdiction, and it works only on copies. Your ASSE 6010 installer decides and signs. Which NFPA 99 edition and plumbing code apply stays with your people and the authority having jurisdiction, and nothing on this page is compliance advice.
Priced per job. You get a range before the proof of concept and a fixed price before you sign.
The range comes on the call, once we know roughly how many medical gas areas your crews test in a quarter and how many testing record forms they use.
// Questions
Medical gas record questions from foremen and PMs
Will the AI mark tests passed or sign the record?
Does this replace the verifier's tests or report?
Our crews write pressures on tape and photograph the gauges. Is that enough?
Which edition of NFPA 99 does the draft follow?
Do patient records or hospital security details have to leave our office?

Rob Eason, founder
// Book a proof-of-concept call
Bring the testing records from your last two hospital jobs.
Half an hour with Rob about your company, your role, the job to start with and roughly how many medical gas areas your crews test in a quarter. Keep logs and drawings in the office until the NDA is signed.
- Co-owned a 60-employee financial services firm and sold his share to his partner.
- Ran GOSO Technologies, a Boston solar company rated 5/5 across 24 Google reviews.
- 5/5 across 83 reviews in HighLevel's Certified Admin Directory.
- 4.3/5 from 6 Google reviews of Massmarket AI.
- Every directory and Google review, critical ones included, is shown word for word at massmarket.ai/reviews.
- Takes every proof-of-concept call himself.